LZSR Current Transducer Sensors

LEM LZSR Current Transducer Sensors are designed for precise measurement of DC, AC, and pulse currents, ranging from 80ARMS to 200ARMS, while ensuring galvanic isolation between primary and secondary circuits. These sensors offer outstanding performance with ultra-low offset drift as low as 3ppm/K, a significant improvement over previous generations that relied on traditional Hall-effect chips. Additional features include reference access, an overcurrent detection output, and operation on a +5V power supply, making the components highly efficient for various industrial applications.

Resultados: 8
Seleccionar Imagen N.° de pieza Fabricante: Descripción Hoja de datos Disponibilidad Precio: (CLP) Filtre los resultados en la tabla por precio unitario en función de su cantidad. Cantidad RoHS Modelo ECAD Régimen de corriente Tipo de sensor Tiempo de respuesta Exactitud Banda de frecuencias Voltaje de alimentación operativo Tipo de salida
LEM Sensores de corriente montados en placa Current Transducer LZSR 100-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 92En existencias
Min.: 1
Mult.: 1

100 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 150-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 81En existencias
Min.: 1
Mult.: 1

150 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 150-P/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 113En existencias
Min.: 1
Mult.: 1

150 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 80-P. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 135En existencias
Min.: 1
Mult.: 1

80 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 100-TP. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the primary and the secondary circuit. 56En existencias
Min.: 1
Mult.: 1

100 A Closed Loop 2 us 1.25 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 150-TP. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 44En existencias
Min.: 1
Mult.: 1

150 A Closed Loop 2 us 1.25 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 200-P/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 35En existencias
60Se espera el 13-08-2026
Min.: 1
Mult.: 1

200 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer LZSR 200-TP/SP1. For the electronic measurement of current: DC, AC, pulsed, with galvanic separation between the prmary and the secondary circuit. 27En existencias
60Se espera el 14-09-2026
Min.: 1
Mult.: 1

200 A Closed Loop 3 us 1.4 % 200 kHz 5 V Digital, Analog